Refrigeration, Air Conditioning & Specialty Gas Recovery EquipmentBrand: KOOLTEC

On-Line Chiller Refrigerant Flushing & Regeneration Equipment

Models in this series (2, select to view specs):
Key Engineering Highlights
Applicable Gases / RefrigerantsR-22, R-134a, R-32
Operating Power / VoltagePower Input: 10.0 HP / Power Input / 7.0 HP
Certifications工研院 TS 防爆型式認證合格 (Ex d IIB T4 / T6 等級)
Country of Origin100% Made in Taiwan (MIT)
Procurement Inquiries & Engineering Consultation
Dedicated Sales Email: [email protected]
International Support Line: +886-7-7874727 (Mon-Fri 08:30 - 17:30 GMT+8)

LTP-052-EXP On-Line Chiller Refrigerant Flushing & Regeneration Equipment is in our Refrigeration, Air Conditioning & Specialty Gas Recovery Equipment category, for R-22. Key specifications: Input Power (HP) 10.0 HP, Weight 560 KG / Weight / 380 KG, Power Input 10.0 HP / Power Input / 7.0 HP.

Core Features & Engineering Principles

  • Capture moisture and particles in refrigerant.
  • Distillation refrigerant and removing sludge oil.
  • Promote E.E.R. in the refrigerator equipment.
  • Easy operation for Liquid Recovery & Recycling in chillers maintenance
  • Fit for 100USRT~1500USRT Refrigerator (1USRT=3024 Kcal/H, 12000 BTU/H)

Specifications by Model

Select a model to expand its full specifications. Other catalog records of the same machine are listed for reference.

LTP-052-EXP (10HP)LTP-052-EXP On-Line Chiller Refrigerant Flushing & Regeneration Equipment
Parameter ItemSpecification ValueUnit
Model No.LTP-052-EXP-
Input Power (HP)10.0 HP-
Refrigerant2,200 KG-
Refrigerant9000KG-
Model NO.LTP-052-EXP / Model NO. / MTP-036-
Dimensions (L x W x H)154L×89W×127H CM / Dimensions / 133L×81W×112H CM-
Weight560 KG / Weight / 380 KG-
Power Input10.0 HP / Power Input / 7.0 HP-
Liquid Recycling Rate3.5~5.0 Kg/M / Liquid Recycling Rate / 4.5~6.0 Kg/M-
Oil DrainAuto & Manual / Oil Drain / Auto & Manual-
Purge ActionSolenoid Valve / Purge Action / Solenoid Valve-
Refrigerant Recovery LimitedVapor & Liquid / Vapor & Liquid / Refrigerant Recovery Limited / Vapor & Liquid / Vapor & Liquid-
◎ Voltage3Ø220V/380V, 50/60HZ ◎ Safety Equipment: Low/High pressure-
◎ Purge TankSUS-304 material.-
◎ AccumulatorSUS-304 material, with-
LTP-052-EXP (Filtration Station)Same machine, reference record
Parameter ItemSpecification ValueUnit
Model NO.LTP-052-EXP / Model NO. / MTP-036-
Dimensions (L x W x H)154L× 89W× 127H CM / Dimensions / 133L× 81W× 112H CM-
Weight560 KG / Weight / 380 KG-
Power Input10.0 HP / Power Input / 7.0 HP-
Liquid Recycling Rate3.5~5.0 Kg/M / Liquid Recycling Rate / 4.5~6.0 Kg/M-
Oil DrainAuto & Manual / Oil Drain / Auto & Manual-
Purge ActionPurge Action-
Refrigerant Recovery LimitedVapor & Liquid / Refrigerant Recovery / Vapor & Liquid-
◎ Voltage3Ø220V/380V, 50/60HZ ◎ Safety Equipment: Low/High pressure-
◎ Purge TankSUS-304 material. line pressure control automatically),-
◎ AccumulatorSUS-304 material, with change filter-drier.-
FeaturesDon’t need stop this refrigerator equipment-
MTP-036 (Closed-Loop)MTP-036 Closed-Loop On-Line Refrigerant Flushing & Purification Machine
Parameter ItemSpecification ValueUnit
Purge ActionSolenoid Valve / Purge Action / Solenoid Valve-
◎ Voltage3Ø220V/380V, 50/60HZ ◎ Safety Equipment: Low/High pressure-
◎ Purge TankSUS-304 material.-
◎ AccumulatorSUS-304 material, with-
FeaturesDon’t need stop this refrigerator equipment-
Model No.MTP-036-
Power Supply3Ø220V/380V, 50/60HZ-
High-Vacuum IntegratedSame machine, reference record
Parameter ItemSpecification ValueUnit
◎ Voltage3Ø ×220V×60HZ , 3Ø ×380V×50/60HZ-
◎ Purge TankMade of SUS-304 material.-
◎ AccumulatorMade of SUS-304 material, with perfect process Heat-Exchanger design.-
◎ Safety EquipmentLow/High pressure control, No-Fuse-Breaker control, Safety Relief-
◎ Power Voltage3Ø 220V/380V, 60/50HZ-
◎ Oil SeparatorSUS-304 material, with Air-Cooling design.-
◎ AccumulatorSUS-304 material, with perfect process Heat-Exchanger design.-
◎ Safety EquipmentLow/High pressure protection control, Safety Relief Valve,-
◎ Liquid PumpRecovery liquid refrigerant and pump out liquid to storage Tank or-
◎ Perfect Control Circuit DesignPC modulator controller, easy maintenance.-